Dakota CMX Corrosion Thickness Gauges

Dakota CMX Corrosion Thickness Gauges

Top of the range and easy to use, the Dakota CMX Corrosion Thickness Gauges provide inspectors with all the features necessary to measure the material and coating thickness at the same time.

  • Summary
    • Summary

    • Dakota CMX3-DL Corrosion Thickness Gauge

      Intelligent

      User definable limits for pass/fail indication

      Set limits for pass/fail indication on individual reading or for each batch with audible & visual warnings.

      Dual Element Transducer

      Powerful

      Store each measurement for further analysis

      Up to 4GB of readings can be saved into the gauge memory as each measurement is taken, which can be downloaded later into an inspection application or into DakMaster Software for further analysis and reporting.

      Dakota CMX3-DL Ultrasonic Corrosion Thickness Gauge measuring on Calibration Block

      Versatile

      Able to measure coating and material thickness

      The Dakota CMX Ultrasonic Thickness Gauges have the ability to measure coatings and material thickness simultaneously while maintaining the ability to locate pits, flaws and defects in the material.

      Dakota CMX3-DL Corrosion Thickness Gauge Screen Close Up

      Customisable

      Choose & customise the reading display

      The Dakota CMX Thickness Gauge range has a choice of display modes allowing the user to select the most appropriate for their needs; Readings, B-Scan, B-Scan combined with readings, Scan bar & the A-Scan on the Dakota CMX2-DL Corrosion Thickness Gauge and Dakota CMX3-DL Corrosion Thickness Gauge.

      The Dakota CMX ultrasonic corrosion thickness gauge is available in four models - from an entry level Dakota CMX1 Ultrasonic Thickness Gauge to the top of the range Dakota CMX3-DL Ultrasonic Thickness Gauge.

      • Range of display & measurement options: Pulse-Echo, Echo-Echo, Pulse-Echo Temp, Comp Mode (PETP), Coating Only Mode (CT), Pulse-Echo Coating Mode (PECT)
      • Manual or automatic gain control (AGC) with adjustable 110dB range
      • Gate control
      • Threshold adjustment
      • 64 User defined setups
      • Multiple language display
      • Multiple calibration and material selection options
      • High speed scan mode: 250 readings per second (Dakota CMX1 Ultrasonic Thickness Gauge and Dakota CMX1-DL Ultrasonic Thickness Gauge), 50 readings per second (Dakota CMX2-DL Ultrasonic Thickness Gauge and Dakota CMX3-DL Ultrasonic Thickness Gauge)
      • A-Scan portrait & landscape views (Dakota CMX3-DL Ultrasonic Thickness Gauge only)
      • Differential and minimal thickness alarm modes
      • Data output and storage: 4GB internal memory
      • Download to DakMaster data management software

      Transducer Options

      A wide range of Corrosion Thickness Transducers available 

      DakMaster™

      From inspection to professional reports at the click of a button.

  • Key Features
    • Key Features

      Dakota CMX Corrosion Thickness Gauges

      Dakota CMX Features Explained

      Repeatability / Stability Indicator

      Consisting of 6 vertical bars, when all the bars are fully illuminated and the last digit on the digital thickness value is stable, the gauge is reliably measuring the material thickness.

      High Speed Scan with Minimum Thickness Display

      By significantly increasing the measurement refresh rate this mode allows the user to make scanned passes over the test material. The smallest thickness value is held in memory and displayed when scanning is complete. This feature can also be used in conjunction with the minimum & maximum limit alarm feature (model dependant).

      Differential Mode

      Once a user defined nominal thickness value has been set, the gauge will display the +/- thickness difference from the nominal value entered.

      Limit Alarm Mode

      The user can define minimum and maximum thickness limits. If the measurement falls outside the upper or lower limit a red LED will light and the beeper sounds. A green LED will light to indicate an acceptable thickness.

      V-Path Correction

      Dual element transducers consist of a probe with two crystals (one to transmit and one to receive the sound pulse). The crystals are separated by an acoustic barrier - generating a 'V-shaped' sound path as the sound travels from one element to the other. This path is slightly longer than the direct path therefore V-path correction is used to calculate the correct thickness

      Measurement Modes Explained

      CG100-PE-Mode

      Pulse - Echo Mode (PE):

      The normal display mode, measures the total thickness from the base of the transducer probe to the material density boundary (typically the back wall). Ideal for pit and flaw detection.

      CG100-EE-Mode_1

      Echo - Echo Mode (EE):

      Also known as the ThruPaint™ Mode, EE ignores the coating thickness, displaying the material thickness from the top surface of the material to the material density boundary.

      CG100-PEPT-Mode

      Pulse - Echo Temp Comp Mode  (PETP):

      Similar to the PE mode, PETP takes into account and compensates for the variations in measurement caused by temperature variations. 

      CG100-EEV-Mode

      Echo - Echo Verify Mode (EEV):

      The echo-echo verify mode measures by comparing the values between 3 reflections and is commonly used to eliminate errors from surface coatings and to make measurements in multiple layered materials.

      CG100-CT-Mode

      Coating Only Mode (CT):

      Displays the thickness of the coating applied to the material.

      CG100-PECT-Mode

      Pulse - Echo Coating Mode (PECT):

      Displays both the material thickness (PE) and the coating thickness (CT) at the same time.

      CG100-FLAW-Mode

      Basic Flaw Mode (FLAW MODE):

      Basic prove-up flaw detection using single element angle beam transducers is available on the CMX2-DL and CMX3-DL corrosion thickness gauges.

      Display Modes Explained

      CG70-B-Scan_2

      Material Thickness Digits Display:

      The standard display on all models, this displays the numerical thickness value in either millimetres (MM)or inches (IN).

      Scan Bar Display:

      A linear graphic display which allows users to graphically monitor changes in thickness readings. As the scale range can be adjusted by the user, this display is ideal for observing tiny variations in material thicknesses.

      B-Scan Display:

      A time based cross sectional 2D block view of the thickness provides a graphical view of the material thickness - ideal for relative depth analysis.

      CG70-A-Scan_1

      A-Scan Display; Full Wave (RF):*

      The A-Scan display shows the sine wave created by the reflected sound, or oscillation, from the material being measured. In RF mode the full wave form is displayed.

      A-Scan Display; Rectified (+ or -):*

      Users can select to view either the positive or the negative cycle of the full waveform (RF). This rectified (RECT) display shows the amplitude of the echo versus the transit time.

       

      * Available on CMX2-DL and CMX3-DL thickness gauge Models only

  • Product Features
    • Product Features
      Dakota CMX Corrosion Thickness Gauges
      Model CMX1 CMX1-DL CMX2-DL CMX3-DL
      Display Mode
      Material thickness digits display
      B-Scan cross sectional display
      Combined B-Scan and digits display
      Coating Thickness Display
      Scan Bar Display
      A-Scan Display
      + Rectified, - Rectified, Full Waveform (RF) Portrait & landscape views
      Measurement Range
      PE: 0.63 - 1219.2mm
      (0.025 - 48”)
      PETP: 0.63 - 1219.2mm
      (0.025 - 48”)
      EE: 2.54 - 152.4mm
      (0.100 - 6.0“)
      EEV: 1.27 - 25.4mm
      (0.050 - 1.0”)
      CT: 0.01 - 2.54mm
      (0.0005 - 0.100”)
      PECT: 0.63 - 1219.2mm
      (0.025 - 48”)
      PECT: 0.01 - 2.54mm
      (0.001 - 0.100")
      PE: 0.63 - 1219.2mm
      (0.025 - 48”)
      PETP: 0.63 - 1219.2mm
      (0.025 - 48”)
      EE: 2.54 - 152.4mm
      (0.100 - 6.0“)
      EEV: 1.27 - 25.4mm
      (0.050 - 1.0”)
      CT: 0.01 - 2.54mm
      (0.0005 - 0.100”)
      PECT: 0.63 - 1219.2mm
      (0.025 - 48”)
      PECT: 0.01 - 2.54mm
      (0.001 - 0.100")
      PE: 0.63 - 1219.2mm
      (0.025 - 48”)
      PETP: 0.63 - 1219.2mm
      (0.025 - 48”)
      EE: 2.54 - 152.4mm
      (0.100 - 6.0“)
      EEV: 1.27 - 25.4mm
      (0.050 - 1.0”)
      CT: 0.01 - 2.54mm
      (0.0005 - 0.100”)
      PECT: 0.63 - 1219.2mm
      (0.025 - 48”)
      PECT: 0.01 - 2.54mm
      (0.001 - 0.100")
      PE: 0.63 - 1219.2mm
      (0.025 - 48”)
      PETP: 0.63 - 1219.2mm
      (0.025 - 48”)
      EE: 2.54 - 152.4mm
      (0.100 - 6.0“)
      EEV: 1.27 - 25.4mm
      (0.050 - 1.0”)
      CT: 0.01 - 2.54mm
      (0.0005 - 0.100”)
      PECT: 0.63 - 1219.2mm
      (0.025 - 48”)
      PECT: 0.01 - 2.54mm
      (0.001 - 0.100")
      Measurement Rate
      Manual
      8 readings per second
      8 readings per second
      8 readings per second
      8 readings per second
      Scan Mode
      250 readings per second
      250 readings per second
      50 readings per second
      50 readings per second
      Scan bar display
      10 readings per second
      10 readings per second
      10 readings per second
      10 readings per second
      Measurement Resolution
      0.01mm (0.001”)
      0.01mm (0.001”)
      0.01mm (0.001”), 0.001mm (0.0001”) selectable
      0.01mm (0.001”), 0.001mm (0.0001”) selectable
      Velocity Calibration Range
      309.88 - 18,542m/s
      (0.0122 - 0.7300in/µs)
      309.88 - 18,542m/s
      (0.0122 - 0.7300in/µs)
      309.88 - 18,542m/s
      (0.0122 - 0.7300in/µs)
      309.88 - 18,542m/s
      (0.0122 - 0.7300in/µs)
      Additional Features
      High Speed Scan Mode
      Differential Mode
      Limit alarm mode
      B-Scan Display Speed
      15 readings per second
      15 readings per second
      15 readings per second
      10 to 200 readings per second
      Flaw Mode
      Basic prove-up flaw detection using single element angle beam transducers
      Basic prove-up flaw detection using single element angle beam transducers
      Calibration Setups
      64 user-definable setups transferable to and from a PC archive
      Gates
      3 fully adjustable gates: start, stop, width & threshold
      3 fully adjustable gates: start, stop, width & threshold
      Damping
      Adjustable damping (50 - 1500ohms)
      Adjustable damping (50 - 1500ohms)
      Pulser Type
      Dual square wave pulsers
      Pulse repetition frequency up to 250Hz
      Dual square wave pulsers
      Pulse repetition frequency up to 250Hz
      Dual square wave pulsers
      Pulse repetition frequency up to 250Hz
      Dual square wave pulsers
      Pulse repetition frequency up to 250Hz
      Gain
      Manual or automatic gain control (AGC) with 110dB range (limited)
      Manual or automatic gain control (AGC) with 110dB range (limited)
      Manual, automatic gain control (AGC) with 110dB range (limited), Linear time dependent gain (TDG) with adjustable slope
      Manual, automatic gain control (AGC) with 110dB range (limited), Linear time dependent gain (TDG) with adjustable slope
      Timing
      Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
      Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
      Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
      Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
      Memory and Data Logging
      • 4GB internal memory
      • Sequential and grid logging
      • Alpha numeric batch identification
      • OBSTRUCT indicates inaccessible locations
      • Bitmap graphic capture and capture viewer
      • 4GB internal memory
      • Sequential and grid logging
      • Alpha numeric batch identification
      • OBSTRUCT indicates inaccessible locations
      • Bitmap graphic capture and capture viewer
      • 4GB internal memory
      • Sequential and grid logging
      • Alpha numeric batch identification
      • OBSTRUCT indicates inaccessible locations
      • Bitmap graphic capture and capture viewer
      • 4GB internal memory
      • Sequential and grid logging
      • Alpha numeric batch identification
      • OBSTRUCT indicates inaccessible locations
      • Bitmap graphic capture and capture viewer
      Calibration Options
      1 - point
      2 - point
      Material selection
      Velocity (speed of sound)
      Transducer Probe Type
      Dual element
      Dual element
      Dual element
      Dual Element, Single Element (1 - 20Mhz), Contact, Matching Layer, Delay Line and Pencil
      Transducer Frequency Range
      1 - 10MHz
      1 - 10MHz
      1 - 10MHz
      1 - 20MHz
      Transducer Recognition
      Automatic & manual - selectable from a list
      Automatic & manual - selectable from a list
      Automatic & manual - selectable from a list
      Automatic & manual - selectable from a list
      V-path / dual path error correction
      Automatic
      Automatic
      Automatic
      Automatic
      Probe Zero
      Automatic & manual (via integrated probe disk)
      Automatic & manual (via integrated probe disk)
      Automatic & manual (via integrated probe disk)
      Automatic & manual (via integrated probe disk)
      Display
      1/8 VGA (greyscale)
      62 x 45.7mm (2.4 x 1.8”) viewable area
      1/8 VGA (greyscale)
      62 x 45.7mm (2.4 x 1.8”) viewable area
      1/8 VGA (greyscale)
      62 x 45.7mm (2.4 x 1.8”) viewable area
      1/4 VGA AMOLED colour display
      57.6 x 43.2mm (2.27 x 1.78”) viewable area
      Landscape Mode
      Display Refresh Rate
      25Hz
      25Hz
      25Hz
      120Hz
      Units (selectable)
      mm or inches
      mm or inches
      mm or inches
      mm or inches
      LED Backlight
      on/off/auto
      on/off/auto
      on/off/auto
      adjustable brightness
      Repeatability / Stability Indicator
      Battery Save Mode
      Auto
      Auto
      Auto
      Auto
      Display Mode
      Material thickness digits display
      Z-170-0005
      Z-171-0005
      Z-172-0005
      Z-187-0005
      B-Scan cross sectional display
      Z-170-0005
      Z-171-0005
      Z-172-0005
      Z-187-0005
      Combined B-Scan and digits display
      Z-170-0005
      Z-171-0005
      Z-172-0005
      Z-187-0005
      Coating Thickness Display
      Z-170-0005
      Z-171-0005
      Z-172-0005
      Z-187-0005
      Scan Bar Display
      Z-170-0005
      Z-171-0005
      Z-172-0005
      Z-187-0005
      A-Scan Display
      Z-170-0005
      Z-171-0005
      Z-172-0005
      Z-187-0005
      + Rectified, - Rectified, Full Waveform (RF) Portrait & landscape views
      Measurement Range
      Z-170-0005
      PE: 0.63 - 1219.2mm
      (0.025 - 48”)
      PETP: 0.63 - 1219.2mm
      (0.025 - 48”)
      EE: 2.54 - 152.4mm
      (0.100 - 6.0“)
      EEV: 1.27 - 25.4mm
      (0.050 - 1.0”)
      CT: 0.01 - 2.54mm
      (0.0005 - 0.100”)
      PECT: 0.63 - 1219.2mm
      (0.025 - 48”)
      PECT: 0.01 - 2.54mm
      (0.001 - 0.100")
      Z-171-0005
      PE: 0.63 - 1219.2mm
      (0.025 - 48”)
      PETP: 0.63 - 1219.2mm
      (0.025 - 48”)
      EE: 2.54 - 152.4mm
      (0.100 - 6.0“)
      EEV: 1.27 - 25.4mm
      (0.050 - 1.0”)
      CT: 0.01 - 2.54mm
      (0.0005 - 0.100”)
      PECT: 0.63 - 1219.2mm
      (0.025 - 48”)
      PECT: 0.01 - 2.54mm
      (0.001 - 0.100")
      Z-172-0005
      PE: 0.63 - 1219.2mm
      (0.025 - 48”)
      PETP: 0.63 - 1219.2mm
      (0.025 - 48”)
      EE: 2.54 - 152.4mm
      (0.100 - 6.0“)
      EEV: 1.27 - 25.4mm
      (0.050 - 1.0”)
      CT: 0.01 - 2.54mm
      (0.0005 - 0.100”)
      PECT: 0.63 - 1219.2mm
      (0.025 - 48”)
      PECT: 0.01 - 2.54mm
      (0.001 - 0.100")
      Z-187-0005
      PE: 0.63 - 1219.2mm
      (0.025 - 48”)
      PETP: 0.63 - 1219.2mm
      (0.025 - 48”)
      EE: 2.54 - 152.4mm
      (0.100 - 6.0“)
      EEV: 1.27 - 25.4mm
      (0.050 - 1.0”)
      CT: 0.01 - 2.54mm
      (0.0005 - 0.100”)
      PECT: 0.63 - 1219.2mm
      (0.025 - 48”)
      PECT: 0.01 - 2.54mm
      (0.001 - 0.100")
      Measurement Rate
      Manual
      Z-170-0005
      8 readings per second
      Z-171-0005
      8 readings per second
      Z-172-0005
      8 readings per second
      Z-187-0005
      8 readings per second
      Scan Mode
      Z-170-0005
      250 readings per second
      Z-171-0005
      250 readings per second
      Z-172-0005
      50 readings per second
      Z-187-0005
      50 readings per second
      Scan bar display
      Z-170-0005
      10 readings per second
      Z-171-0005
      10 readings per second
      Z-172-0005
      10 readings per second
      Z-187-0005
      10 readings per second
      Measurement Resolution
      Z-170-0005
      0.01mm (0.001”)
      Z-171-0005
      0.01mm (0.001”)
      Z-172-0005
      0.01mm (0.001”), 0.001mm (0.0001”) selectable
      Z-187-0005
      0.01mm (0.001”), 0.001mm (0.0001”) selectable
      Velocity Calibration Range
      Z-170-0005
      309.88 - 18,542m/s
      (0.0122 - 0.7300in/µs)
      Z-171-0005
      309.88 - 18,542m/s
      (0.0122 - 0.7300in/µs)
      Z-172-0005
      309.88 - 18,542m/s
      (0.0122 - 0.7300in/µs)
      Z-187-0005
      309.88 - 18,542m/s
      (0.0122 - 0.7300in/µs)
      Additional Features
      High Speed Scan Mode
      Z-170-0005
      Z-171-0005
      Z-172-0005
      Z-187-0005
      Differential Mode
      Z-170-0005
      Z-171-0005
      Z-172-0005
      Z-187-0005
      Limit alarm mode
      Z-170-0005
      Z-171-0005
      Z-172-0005
      Z-187-0005
      B-Scan Display Speed
      Z-170-0005
      15 readings per second
      Z-171-0005
      15 readings per second
      Z-172-0005
      15 readings per second
      Z-187-0005
      10 to 200 readings per second
      Flaw Mode
      Z-170-0005
      Z-171-0005
      Z-172-0005
      Basic prove-up flaw detection using single element angle beam transducers
      Z-187-0005
      Basic prove-up flaw detection using single element angle beam transducers
      Calibration Setups
      Z-170-0005
      Z-171-0005
      Z-172-0005
      Z-187-0005
      64 user-definable setups transferable to and from a PC archive
      Gates
      Z-170-0005
      Z-171-0005
      Z-172-0005
      3 fully adjustable gates: start, stop, width & threshold
      Z-187-0005
      3 fully adjustable gates: start, stop, width & threshold
      Damping
      Z-170-0005
      Z-171-0005
      Z-172-0005
      Adjustable damping (50 - 1500ohms)
      Z-187-0005
      Adjustable damping (50 - 1500ohms)
      Pulser Type
      Z-170-0005
      Dual square wave pulsers
      Pulse repetition frequency up to 250Hz
      Z-171-0005
      Dual square wave pulsers
      Pulse repetition frequency up to 250Hz
      Z-172-0005
      Dual square wave pulsers
      Pulse repetition frequency up to 250Hz
      Z-187-0005
      Dual square wave pulsers
      Pulse repetition frequency up to 250Hz
      Gain
      Z-170-0005
      Manual or automatic gain control (AGC) with 110dB range (limited)
      Z-171-0005
      Manual or automatic gain control (AGC) with 110dB range (limited)
      Z-172-0005
      Manual, automatic gain control (AGC) with 110dB range (limited), Linear time dependent gain (TDG) with adjustable slope
      Z-187-0005
      Manual, automatic gain control (AGC) with 110dB range (limited), Linear time dependent gain (TDG) with adjustable slope
      Timing
      Z-170-0005
      Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
      Z-171-0005
      Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
      Z-172-0005
      Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
      Z-187-0005
      Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
      Memory and Data Logging
      Z-170-0005
      • 4GB internal memory
      • Sequential and grid logging
      • Alpha numeric batch identification
      • OBSTRUCT indicates inaccessible locations
      • Bitmap graphic capture and capture viewer
      Z-171-0005
      • 4GB internal memory
      • Sequential and grid logging
      • Alpha numeric batch identification
      • OBSTRUCT indicates inaccessible locations
      • Bitmap graphic capture and capture viewer
      Z-172-0005
      • 4GB internal memory
      • Sequential and grid logging
      • Alpha numeric batch identification
      • OBSTRUCT indicates inaccessible locations
      • Bitmap graphic capture and capture viewer
      Z-187-0005
      • 4GB internal memory
      • Sequential and grid logging
      • Alpha numeric batch identification
      • OBSTRUCT indicates inaccessible locations
      • Bitmap graphic capture and capture viewer
      Calibration Options
      1 - point
      Z-170-0005
      Z-171-0005
      Z-172-0005
      Z-187-0005
      2 - point
      Z-170-0005
      Z-171-0005
      Z-172-0005
      Z-187-0005
      Material selection
      Z-170-0005
      Z-171-0005
      Z-172-0005
      Z-187-0005
      Velocity (speed of sound)
      Z-170-0005
      Z-171-0005
      Z-172-0005
      Z-187-0005
      Transducer Probe Type
      Z-170-0005
      Dual element
      Z-171-0005
      Dual element
      Z-172-0005
      Dual element
      Z-187-0005
      Dual Element, Single Element (1 - 20Mhz), Contact, Matching Layer, Delay Line and Pencil
      Transducer Frequency Range
      Z-170-0005
      1 - 10MHz
      Z-171-0005
      1 - 10MHz
      Z-172-0005
      1 - 10MHz
      Z-187-0005
      1 - 20MHz
      Transducer Recognition
      Z-170-0005
      Automatic & manual - selectable from a list
      Z-171-0005
      Automatic & manual - selectable from a list
      Z-172-0005
      Automatic & manual - selectable from a list
      Z-187-0005
      Automatic & manual - selectable from a list
      V-path / dual path error correction
      Z-170-0005
      Automatic
      Z-171-0005
      Automatic
      Z-172-0005
      Automatic
      Z-187-0005
      Automatic
      Probe Zero
      Z-170-0005
      Automatic & manual (via integrated probe disk)
      Z-171-0005
      Automatic & manual (via integrated probe disk)
      Z-172-0005
      Automatic & manual (via integrated probe disk)
      Z-187-0005
      Automatic & manual (via integrated probe disk)
      Display
      Z-170-0005
      1/8 VGA (greyscale)
      62 x 45.7mm (2.4 x 1.8”) viewable area
      Z-171-0005
      1/8 VGA (greyscale)
      62 x 45.7mm (2.4 x 1.8”) viewable area
      Z-172-0005
      1/8 VGA (greyscale)
      62 x 45.7mm (2.4 x 1.8”) viewable area
      Z-187-0005
      1/4 VGA AMOLED colour display
      57.6 x 43.2mm (2.27 x 1.78”) viewable area
      Landscape Mode
      Display Refresh Rate
      Z-170-0005
      25Hz
      Z-171-0005
      25Hz
      Z-172-0005
      25Hz
      Z-187-0005
      120Hz
      Units (selectable)
      Z-170-0005
      mm or inches
      Z-171-0005
      mm or inches
      Z-172-0005
      mm or inches
      Z-187-0005
      mm or inches
      LED Backlight
      Z-170-0005
      on/off/auto
      Z-171-0005
      on/off/auto
      Z-172-0005
      on/off/auto
      Z-187-0005
      adjustable brightness
      Repeatability / Stability Indicator
      Z-170-0005
      Z-171-0005
      Z-172-0005
      Z-187-0005
      Battery Save Mode
      Z-170-0005
      Auto
      Z-171-0005
      Auto
      Z-172-0005
      Auto
      Z-187-0005
      Auto

      1 Measuring range & accuracy depends on material, surface conditions and the transducer selected

  • Technical Information
    • Technical Specification
      Dakota CMX Corrosion Thickness Gauges
      Part Number Description Certificate
      Z-170-0005 Dakota CMX1 Thickness Gauge (CMX)
      Calibration Certificate supplied as standard
      Z-171-0005 Dakota CMX1-DL Thickness Gauge (CMX-DL)
      Calibration Certificate supplied as standard
      Z-172-0005 Dakota CMX2-DL Thickness Gauge (CMX-DL+)
      Calibration Certificate supplied as standard
      Z-187-0005 Dakota CMX3-DL Thickness Gauge (CMX-DL+ Colour)
      Calibration Certificate supplied as standard
      Transducer Probe Type Dual Element
      Measurement Accuracy1 0.01mm (0.001”)
      Memory 4GB Internal Memory
      Operating Temperature -10 to 60ºC (14 to 140ºF)
      Data Output USB
      Power Supply 3 x AA batteries and via USB
      Battery Life Alkaline: greyscale 35 hrs, colour 12 hrs, Nicad: greyscale 10 hrs, colour 5 hrs, NI-MH: greyscale 35 hrs, colour 12 hrs
      Gauge Weight 383g (13.5oz) - including batteries
      Gauge Dimensions 63.5 x 165 x 31.5mm (2.5 x 6.5 x 1.24”)
      Packing List Unit, Selectable Transducer, Couplant, Manual, Plastic Carrying Case, Certificate of Calibration and AA Batteries. PC Software and Data Transfer Cable included with data logging gauges.
      1Measuring range & accuracy depends on material, surface conditions and the transducer selected
      2Approximate battery life, when in continuous measurement mode.
      Certificate of Calibration supplied as standard.
  • Standards
    • Standards
      Dakota CMX Corrosion Thickness Gauges

      Factory calibration traceable to NIST & MIL-STD-45662

  • Downloads
    • Downloads
        • Dakota CMX1 Thickness Gauge (CMX) Instruction Manual

        • Dakota CMX1-DL Thickness Gauge (CMX-DL) Instruction Manual

        • Dakota CMX2-DL Thickness Gauge (CMX-DL+) Instruction Manual

        • Dakota CMX3-DL Thickness Gauge (CMX-DL+ Colour) Instruction Manual

  • Part Numbers
    • Part Numbers
      Dakota CMX Corrosion Thickness Gauges
      • Dakota CMX1 Corrosion Thickness Gauge
        • Part Number : Z-170-0005
      • Dakota CMX1-DL Corrosion Thickness Gauge
        • Part Number : Z-171-0005
      • Dakota CMX2-DL Corrosion Thickness Gauge
        • Part Number : Z-172-0005
      • Dakota CMX3-DL Corrosion Thickness Gauge
        • Part Number : Z-187-0005

Dakota CMX Corrosion Thickness Gauges

Dakota CMX Corrosion Thickness Gauges

Top of the range and easy to use, the Dakota CMX Corrosion Thickness Gauges provide inspectors with all the features necessary to measure the material and coating thickness at the same time.

Dakota CMX3-DL Corrosion Thickness Gauge

Intelligent

User definable limits for pass/fail indication

Set limits for pass/fail indication on individual reading or for each batch with audible & visual warnings.

Dual Element Transducer

Powerful

Store each measurement for further analysis

Up to 4GB of readings can be saved into the gauge memory as each measurement is taken, which can be downloaded later into an inspection application or into DakMaster Software for further analysis and reporting.

Dakota CMX3-DL Ultrasonic Corrosion Thickness Gauge measuring on Calibration Block

Versatile

Able to measure coating and material thickness

The Dakota CMX Ultrasonic Thickness Gauges have the ability to measure coatings and material thickness simultaneously while maintaining the ability to locate pits, flaws and defects in the material.

Dakota CMX3-DL Corrosion Thickness Gauge Screen Close Up

Customisable

Choose & customise the reading display

The Dakota CMX Thickness Gauge range has a choice of display modes allowing the user to select the most appropriate for their needs; Readings, B-Scan, B-Scan combined with readings, Scan bar & the A-Scan on the Dakota CMX2-DL Corrosion Thickness Gauge and Dakota CMX3-DL Corrosion Thickness Gauge.

Summary

Dakota CMX Corrosion Thickness Gauges

The Dakota CMX ultrasonic corrosion thickness gauge is available in four models - from an entry level Dakota CMX1 Ultrasonic Thickness Gauge to the top of the range Dakota CMX3-DL Ultrasonic Thickness Gauge.

  • Range of display & measurement options: Pulse-Echo, Echo-Echo, Pulse-Echo Temp, Comp Mode (PETP), Coating Only Mode (CT), Pulse-Echo Coating Mode (PECT)
  • Manual or automatic gain control (AGC) with adjustable 110dB range
  • Gate control
  • Threshold adjustment
  • 64 User defined setups
  • Multiple language display
  • Multiple calibration and material selection options
  • High speed scan mode: 250 readings per second (Dakota CMX1 Ultrasonic Thickness Gauge and Dakota CMX1-DL Ultrasonic Thickness Gauge), 50 readings per second (Dakota CMX2-DL Ultrasonic Thickness Gauge and Dakota CMX3-DL Ultrasonic Thickness Gauge)
  • A-Scan portrait & landscape views (Dakota CMX3-DL Ultrasonic Thickness Gauge only)
  • Differential and minimal thickness alarm modes
  • Data output and storage: 4GB internal memory
  • Download to DakMaster data management software

Transducer Options

A wide range of Corrosion Thickness Transducers available 

DakMaster™

From inspection to professional reports at the click of a button.

Downloads
    • Dakota CMX1 Thickness Gauge (CMX) Instruction Manual

    • Dakota CMX1-DL Thickness Gauge (CMX-DL) Instruction Manual

    • Dakota CMX2-DL Thickness Gauge (CMX-DL+) Instruction Manual

    • Dakota CMX3-DL Thickness Gauge (CMX-DL+ Colour) Instruction Manual

Key Features

Dakota CMX Corrosion Thickness Gauges

Dakota CMX Features Explained

Repeatability / Stability Indicator

Consisting of 6 vertical bars, when all the bars are fully illuminated and the last digit on the digital thickness value is stable, the gauge is reliably measuring the material thickness.

High Speed Scan with Minimum Thickness Display

By significantly increasing the measurement refresh rate this mode allows the user to make scanned passes over the test material. The smallest thickness value is held in memory and displayed when scanning is complete. This feature can also be used in conjunction with the minimum & maximum limit alarm feature (model dependant).

Differential Mode

Once a user defined nominal thickness value has been set, the gauge will display the +/- thickness difference from the nominal value entered.

Limit Alarm Mode

The user can define minimum and maximum thickness limits. If the measurement falls outside the upper or lower limit a red LED will light and the beeper sounds. A green LED will light to indicate an acceptable thickness.

V-Path Correction

Dual element transducers consist of a probe with two crystals (one to transmit and one to receive the sound pulse). The crystals are separated by an acoustic barrier - generating a 'V-shaped' sound path as the sound travels from one element to the other. This path is slightly longer than the direct path therefore V-path correction is used to calculate the correct thickness

Measurement Modes Explained

CG100-PE-Mode

Pulse - Echo Mode (PE):

The normal display mode, measures the total thickness from the base of the transducer probe to the material density boundary (typically the back wall). Ideal for pit and flaw detection.

CG100-EE-Mode_1

Echo - Echo Mode (EE):

Also known as the ThruPaint™ Mode, EE ignores the coating thickness, displaying the material thickness from the top surface of the material to the material density boundary.

CG100-PEPT-Mode

Pulse - Echo Temp Comp Mode  (PETP):

Similar to the PE mode, PETP takes into account and compensates for the variations in measurement caused by temperature variations. 

CG100-EEV-Mode

Echo - Echo Verify Mode (EEV):

The echo-echo verify mode measures by comparing the values between 3 reflections and is commonly used to eliminate errors from surface coatings and to make measurements in multiple layered materials.

CG100-CT-Mode

Coating Only Mode (CT):

Displays the thickness of the coating applied to the material.

CG100-PECT-Mode

Pulse - Echo Coating Mode (PECT):

Displays both the material thickness (PE) and the coating thickness (CT) at the same time.

CG100-FLAW-Mode

Basic Flaw Mode (FLAW MODE):

Basic prove-up flaw detection using single element angle beam transducers is available on the CMX2-DL and CMX3-DL corrosion thickness gauges.

Display Modes Explained

CG70-B-Scan_2

Material Thickness Digits Display:

The standard display on all models, this displays the numerical thickness value in either millimetres (MM)or inches (IN).

Scan Bar Display:

A linear graphic display which allows users to graphically monitor changes in thickness readings. As the scale range can be adjusted by the user, this display is ideal for observing tiny variations in material thicknesses.

B-Scan Display:

A time based cross sectional 2D block view of the thickness provides a graphical view of the material thickness - ideal for relative depth analysis.

CG70-A-Scan_1

A-Scan Display; Full Wave (RF):*

The A-Scan display shows the sine wave created by the reflected sound, or oscillation, from the material being measured. In RF mode the full wave form is displayed.

A-Scan Display; Rectified (+ or -):*

Users can select to view either the positive or the negative cycle of the full waveform (RF). This rectified (RECT) display shows the amplitude of the echo versus the transit time.

 

* Available on CMX2-DL and CMX3-DL thickness gauge Models only

Product Features
Dakota CMX Corrosion Thickness Gauges
Model CMX1 CMX1-DL CMX2-DL CMX3-DL
Display Mode
Material thickness digits display
B-Scan cross sectional display
Combined B-Scan and digits display
Coating Thickness Display
Scan Bar Display
A-Scan Display
+ Rectified, - Rectified, Full Waveform (RF) Portrait & landscape views
Measurement Range
PE: 0.63 - 1219.2mm
(0.025 - 48”)
PETP: 0.63 - 1219.2mm
(0.025 - 48”)
EE: 2.54 - 152.4mm
(0.100 - 6.0“)
EEV: 1.27 - 25.4mm
(0.050 - 1.0”)
CT: 0.01 - 2.54mm
(0.0005 - 0.100”)
PECT: 0.63 - 1219.2mm
(0.025 - 48”)
PECT: 0.01 - 2.54mm
(0.001 - 0.100")
PE: 0.63 - 1219.2mm
(0.025 - 48”)
PETP: 0.63 - 1219.2mm
(0.025 - 48”)
EE: 2.54 - 152.4mm
(0.100 - 6.0“)
EEV: 1.27 - 25.4mm
(0.050 - 1.0”)
CT: 0.01 - 2.54mm
(0.0005 - 0.100”)
PECT: 0.63 - 1219.2mm
(0.025 - 48”)
PECT: 0.01 - 2.54mm
(0.001 - 0.100")
PE: 0.63 - 1219.2mm
(0.025 - 48”)
PETP: 0.63 - 1219.2mm
(0.025 - 48”)
EE: 2.54 - 152.4mm
(0.100 - 6.0“)
EEV: 1.27 - 25.4mm
(0.050 - 1.0”)
CT: 0.01 - 2.54mm
(0.0005 - 0.100”)
PECT: 0.63 - 1219.2mm
(0.025 - 48”)
PECT: 0.01 - 2.54mm
(0.001 - 0.100")
PE: 0.63 - 1219.2mm
(0.025 - 48”)
PETP: 0.63 - 1219.2mm
(0.025 - 48”)
EE: 2.54 - 152.4mm
(0.100 - 6.0“)
EEV: 1.27 - 25.4mm
(0.050 - 1.0”)
CT: 0.01 - 2.54mm
(0.0005 - 0.100”)
PECT: 0.63 - 1219.2mm
(0.025 - 48”)
PECT: 0.01 - 2.54mm
(0.001 - 0.100")
Measurement Rate
Manual
8 readings per second
8 readings per second
8 readings per second
8 readings per second
Scan Mode
250 readings per second
250 readings per second
50 readings per second
50 readings per second
Scan bar display
10 readings per second
10 readings per second
10 readings per second
10 readings per second
Measurement Resolution
0.01mm (0.001”)
0.01mm (0.001”)
0.01mm (0.001”), 0.001mm (0.0001”) selectable
0.01mm (0.001”), 0.001mm (0.0001”) selectable
Velocity Calibration Range
309.88 - 18,542m/s
(0.0122 - 0.7300in/µs)
309.88 - 18,542m/s
(0.0122 - 0.7300in/µs)
309.88 - 18,542m/s
(0.0122 - 0.7300in/µs)
309.88 - 18,542m/s
(0.0122 - 0.7300in/µs)
Additional Features
High Speed Scan Mode
Differential Mode
Limit alarm mode
B-Scan Display Speed
15 readings per second
15 readings per second
15 readings per second
10 to 200 readings per second
Flaw Mode
Basic prove-up flaw detection using single element angle beam transducers
Basic prove-up flaw detection using single element angle beam transducers
Calibration Setups
64 user-definable setups transferable to and from a PC archive
Gates
3 fully adjustable gates: start, stop, width & threshold
3 fully adjustable gates: start, stop, width & threshold
Damping
Adjustable damping (50 - 1500ohms)
Adjustable damping (50 - 1500ohms)
Pulser Type
Dual square wave pulsers
Pulse repetition frequency up to 250Hz
Dual square wave pulsers
Pulse repetition frequency up to 250Hz
Dual square wave pulsers
Pulse repetition frequency up to 250Hz
Dual square wave pulsers
Pulse repetition frequency up to 250Hz
Gain
Manual or automatic gain control (AGC) with 110dB range (limited)
Manual or automatic gain control (AGC) with 110dB range (limited)
Manual, automatic gain control (AGC) with 110dB range (limited), Linear time dependent gain (TDG) with adjustable slope
Manual, automatic gain control (AGC) with 110dB range (limited), Linear time dependent gain (TDG) with adjustable slope
Timing
Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
Memory and Data Logging
• 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewer
• 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewer
• 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewer
• 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewer
Calibration Options
1 - point
2 - point
Material selection
Velocity (speed of sound)
Transducer Probe Type
Dual element
Dual element
Dual element
Dual Element, Single Element (1 - 20Mhz), Contact, Matching Layer, Delay Line and Pencil
Transducer Frequency Range
1 - 10MHz
1 - 10MHz
1 - 10MHz
1 - 20MHz
Transducer Recognition
Automatic & manual - selectable from a list
Automatic & manual - selectable from a list
Automatic & manual - selectable from a list
Automatic & manual - selectable from a list
V-path / dual path error correction
Automatic
Automatic
Automatic
Automatic
Probe Zero
Automatic & manual (via integrated probe disk)
Automatic & manual (via integrated probe disk)
Automatic & manual (via integrated probe disk)
Automatic & manual (via integrated probe disk)
Display
1/8 VGA (greyscale)
62 x 45.7mm (2.4 x 1.8”) viewable area
1/8 VGA (greyscale)
62 x 45.7mm (2.4 x 1.8”) viewable area
1/8 VGA (greyscale)
62 x 45.7mm (2.4 x 1.8”) viewable area
1/4 VGA AMOLED colour display
57.6 x 43.2mm (2.27 x 1.78”) viewable area
Landscape Mode
Display Refresh Rate
25Hz
25Hz
25Hz
120Hz
Units (selectable)
mm or inches
mm or inches
mm or inches
mm or inches
LED Backlight
on/off/auto
on/off/auto
on/off/auto
adjustable brightness
Repeatability / Stability Indicator
Battery Save Mode
Auto
Auto
Auto
Auto
Display Mode
Material thickness digits display
Z-170-0005
Z-171-0005
Z-172-0005
Z-187-0005
B-Scan cross sectional display
Z-170-0005
Z-171-0005
Z-172-0005
Z-187-0005
Combined B-Scan and digits display
Z-170-0005
Z-171-0005
Z-172-0005
Z-187-0005
Coating Thickness Display
Z-170-0005
Z-171-0005
Z-172-0005
Z-187-0005
Scan Bar Display
Z-170-0005
Z-171-0005
Z-172-0005
Z-187-0005
A-Scan Display
Z-170-0005
Z-171-0005
Z-172-0005
Z-187-0005
+ Rectified, - Rectified, Full Waveform (RF) Portrait & landscape views
Measurement Range
Z-170-0005
PE: 0.63 - 1219.2mm
(0.025 - 48”)
PETP: 0.63 - 1219.2mm
(0.025 - 48”)
EE: 2.54 - 152.4mm
(0.100 - 6.0“)
EEV: 1.27 - 25.4mm
(0.050 - 1.0”)
CT: 0.01 - 2.54mm
(0.0005 - 0.100”)
PECT: 0.63 - 1219.2mm
(0.025 - 48”)
PECT: 0.01 - 2.54mm
(0.001 - 0.100")
Z-171-0005
PE: 0.63 - 1219.2mm
(0.025 - 48”)
PETP: 0.63 - 1219.2mm
(0.025 - 48”)
EE: 2.54 - 152.4mm
(0.100 - 6.0“)
EEV: 1.27 - 25.4mm
(0.050 - 1.0”)
CT: 0.01 - 2.54mm
(0.0005 - 0.100”)
PECT: 0.63 - 1219.2mm
(0.025 - 48”)
PECT: 0.01 - 2.54mm
(0.001 - 0.100")
Z-172-0005
PE: 0.63 - 1219.2mm
(0.025 - 48”)
PETP: 0.63 - 1219.2mm
(0.025 - 48”)
EE: 2.54 - 152.4mm
(0.100 - 6.0“)
EEV: 1.27 - 25.4mm
(0.050 - 1.0”)
CT: 0.01 - 2.54mm
(0.0005 - 0.100”)
PECT: 0.63 - 1219.2mm
(0.025 - 48”)
PECT: 0.01 - 2.54mm
(0.001 - 0.100")
Z-187-0005
PE: 0.63 - 1219.2mm
(0.025 - 48”)
PETP: 0.63 - 1219.2mm
(0.025 - 48”)
EE: 2.54 - 152.4mm
(0.100 - 6.0“)
EEV: 1.27 - 25.4mm
(0.050 - 1.0”)
CT: 0.01 - 2.54mm
(0.0005 - 0.100”)
PECT: 0.63 - 1219.2mm
(0.025 - 48”)
PECT: 0.01 - 2.54mm
(0.001 - 0.100")
Measurement Rate
Manual
Z-170-0005
8 readings per second
Z-171-0005
8 readings per second
Z-172-0005
8 readings per second
Z-187-0005
8 readings per second
Scan Mode
Z-170-0005
250 readings per second
Z-171-0005
250 readings per second
Z-172-0005
50 readings per second
Z-187-0005
50 readings per second
Scan bar display
Z-170-0005
10 readings per second
Z-171-0005
10 readings per second
Z-172-0005
10 readings per second
Z-187-0005
10 readings per second
Measurement Resolution
Z-170-0005
0.01mm (0.001”)
Z-171-0005
0.01mm (0.001”)
Z-172-0005
0.01mm (0.001”), 0.001mm (0.0001”) selectable
Z-187-0005
0.01mm (0.001”), 0.001mm (0.0001”) selectable
Velocity Calibration Range
Z-170-0005
309.88 - 18,542m/s
(0.0122 - 0.7300in/µs)
Z-171-0005
309.88 - 18,542m/s
(0.0122 - 0.7300in/µs)
Z-172-0005
309.88 - 18,542m/s
(0.0122 - 0.7300in/µs)
Z-187-0005
309.88 - 18,542m/s
(0.0122 - 0.7300in/µs)
Additional Features
High Speed Scan Mode
Z-170-0005
Z-171-0005
Z-172-0005
Z-187-0005
Differential Mode
Z-170-0005
Z-171-0005
Z-172-0005
Z-187-0005
Limit alarm mode
Z-170-0005
Z-171-0005
Z-172-0005
Z-187-0005
B-Scan Display Speed
Z-170-0005
15 readings per second
Z-171-0005
15 readings per second
Z-172-0005
15 readings per second
Z-187-0005
10 to 200 readings per second
Flaw Mode
Z-170-0005
Z-171-0005
Z-172-0005
Basic prove-up flaw detection using single element angle beam transducers
Z-187-0005
Basic prove-up flaw detection using single element angle beam transducers
Calibration Setups
Z-170-0005
Z-171-0005
Z-172-0005
Z-187-0005
64 user-definable setups transferable to and from a PC archive
Gates
Z-170-0005
Z-171-0005
Z-172-0005
3 fully adjustable gates: start, stop, width & threshold
Z-187-0005
3 fully adjustable gates: start, stop, width & threshold
Damping
Z-170-0005
Z-171-0005
Z-172-0005
Adjustable damping (50 - 1500ohms)
Z-187-0005
Adjustable damping (50 - 1500ohms)
Pulser Type
Z-170-0005
Dual square wave pulsers
Pulse repetition frequency up to 250Hz
Z-171-0005
Dual square wave pulsers
Pulse repetition frequency up to 250Hz
Z-172-0005
Dual square wave pulsers
Pulse repetition frequency up to 250Hz
Z-187-0005
Dual square wave pulsers
Pulse repetition frequency up to 250Hz
Gain
Z-170-0005
Manual or automatic gain control (AGC) with 110dB range (limited)
Z-171-0005
Manual or automatic gain control (AGC) with 110dB range (limited)
Z-172-0005
Manual, automatic gain control (AGC) with 110dB range (limited), Linear time dependent gain (TDG) with adjustable slope
Z-187-0005
Manual, automatic gain control (AGC) with 110dB range (limited), Linear time dependent gain (TDG) with adjustable slope
Timing
Z-170-0005
Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
Z-171-0005
Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
Z-172-0005
Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
Z-187-0005
Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
Memory and Data Logging
Z-170-0005
• 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewer
Z-171-0005
• 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewer
Z-172-0005
• 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewer
Z-187-0005
• 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewer
Calibration Options
1 - point
Z-170-0005
Z-171-0005
Z-172-0005
Z-187-0005
2 - point
Z-170-0005
Z-171-0005
Z-172-0005
Z-187-0005
Material selection
Z-170-0005
Z-171-0005
Z-172-0005
Z-187-0005
Velocity (speed of sound)
Z-170-0005
Z-171-0005
Z-172-0005
Z-187-0005
Transducer Probe Type
Z-170-0005
Dual element
Z-171-0005
Dual element
Z-172-0005
Dual element
Z-187-0005
Dual Element, Single Element (1 - 20Mhz), Contact, Matching Layer, Delay Line and Pencil
Transducer Frequency Range
Z-170-0005
1 - 10MHz
Z-171-0005
1 - 10MHz
Z-172-0005
1 - 10MHz
Z-187-0005
1 - 20MHz
Transducer Recognition
Z-170-0005
Automatic & manual - selectable from a list
Z-171-0005
Automatic & manual - selectable from a list
Z-172-0005
Automatic & manual - selectable from a list
Z-187-0005
Automatic & manual - selectable from a list
V-path / dual path error correction
Z-170-0005
Automatic
Z-171-0005
Automatic
Z-172-0005
Automatic
Z-187-0005
Automatic
Probe Zero
Z-170-0005
Automatic & manual (via integrated probe disk)
Z-171-0005
Automatic & manual (via integrated probe disk)
Z-172-0005
Automatic & manual (via integrated probe disk)
Z-187-0005
Automatic & manual (via integrated probe disk)
Display
Z-170-0005
1/8 VGA (greyscale)
62 x 45.7mm (2.4 x 1.8”) viewable area
Z-171-0005
1/8 VGA (greyscale)
62 x 45.7mm (2.4 x 1.8”) viewable area
Z-172-0005
1/8 VGA (greyscale)
62 x 45.7mm (2.4 x 1.8”) viewable area
Z-187-0005
1/4 VGA AMOLED colour display
57.6 x 43.2mm (2.27 x 1.78”) viewable area
Landscape Mode
Display Refresh Rate
Z-170-0005
25Hz
Z-171-0005
25Hz
Z-172-0005
25Hz
Z-187-0005
120Hz
Units (selectable)
Z-170-0005
mm or inches
Z-171-0005
mm or inches
Z-172-0005
mm or inches
Z-187-0005
mm or inches
LED Backlight
Z-170-0005
on/off/auto
Z-171-0005
on/off/auto
Z-172-0005
on/off/auto
Z-187-0005
adjustable brightness
Repeatability / Stability Indicator
Z-170-0005
Z-171-0005
Z-172-0005
Z-187-0005
Battery Save Mode
Z-170-0005
Auto
Z-171-0005
Auto
Z-172-0005
Auto
Z-187-0005
Auto

1 Measuring range & accuracy depends on material, surface conditions and the transducer selected

Technical Specification
Dakota CMX Corrosion Thickness Gauges
Part Number Description Certificate
Z-170-0005 Dakota CMX1 Thickness Gauge (CMX)
Calibration Certificate supplied as standard
Z-171-0005 Dakota CMX1-DL Thickness Gauge (CMX-DL)
Calibration Certificate supplied as standard
Z-172-0005 Dakota CMX2-DL Thickness Gauge (CMX-DL+)
Calibration Certificate supplied as standard
Z-187-0005 Dakota CMX3-DL Thickness Gauge (CMX-DL+ Colour)
Calibration Certificate supplied as standard
Transducer Probe Type Dual Element
Measurement Accuracy1 0.01mm (0.001”)
Memory 4GB Internal Memory
Operating Temperature -10 to 60ºC (14 to 140ºF)
Data Output USB
Power Supply 3 x AA batteries and via USB
Battery Life Alkaline: greyscale 35 hrs, colour 12 hrs, Nicad: greyscale 10 hrs, colour 5 hrs, NI-MH: greyscale 35 hrs, colour 12 hrs
Gauge Weight 383g (13.5oz) - including batteries
Gauge Dimensions 63.5 x 165 x 31.5mm (2.5 x 6.5 x 1.24”)
Packing List Unit, Selectable Transducer, Couplant, Manual, Plastic Carrying Case, Certificate of Calibration and AA Batteries. PC Software and Data Transfer Cable included with data logging gauges.
1Measuring range & accuracy depends on material, surface conditions and the transducer selected
2Approximate battery life, when in continuous measurement mode.
Certificate of Calibration supplied as standard.
Standards
Dakota CMX Corrosion Thickness Gauges

Factory calibration traceable to NIST & MIL-STD-45662

Part Numbers
Dakota CMX Corrosion Thickness Gauges
  • Dakota CMX1 Corrosion Thickness Gauge
    • Part Number : Z-170-0005
  • Dakota CMX1-DL Corrosion Thickness Gauge
    • Part Number : Z-171-0005
  • Dakota CMX2-DL Corrosion Thickness Gauge
    • Part Number : Z-172-0005
  • Dakota CMX3-DL Corrosion Thickness Gauge
    • Part Number : Z-187-0005