Dakota MX Corrosion Thickness Gauges

Dakota MX2-DL Thickness Gauge
CG70-Transducer-intro

The Dakota MX Corrosion Thickness Gauge range have large, easy to read displays and provides users with A and B-Scan options for accurate interpretation of measurements.

  • Summary
    • Summary

    • Dakota MX2-DL Thickness Gauge measuring container

      Versatile

      Measures uncoated & coated surfaces

      Flexible & easy to use, the Dakota MX Corrosion Thickness range doesn’t just measure uncoated surfaces but can also measure coated surfaces. Using Echo Echo ThruPaint™ Mode (EE), coatings up to 1mm (40mils) are ignored.

      CG70-Powerful

      Powerful

      Store up to 4GB of readings and waveforms or B-Scans

      Taking 250 readings per second in scan mode, the internal data logger stores up to 4GB of readings together with their waveforms.

      Dakota MX Corrosion Thickness Gauge Screen Close Up

      Customisable

      Choose & customise the reading display

      The Dakota MX ultrasonic thickness gauge range has a choice of display modes allowing the user to select the most appropriate for their needs; Readings, B-Scan, B-Scan combined with readings, Scan bar & the A-Scan on the MX2-DL Corrosion Thickness Gauge.

      The Dakota MX corrosion thickness gauge is available in two models: MX1-DL Thickness Gauge and MX2-DL Thickness Gauge. Both models offer 2D cross sectional block view, providing a graphical representation of a material's thickness, ideal for accurate analysis and identification of pits and corroded areas.

      MX1-DL Ultrasonic Thickness Gauge: Taking 250 readings per second in scan mode, the internal data logger stores up to 4GB worth of data together with their waveforms.

      MX2-DL Ultrasonic Thickness Gauge: As well as all the features of the MX1-DL Thickness Gauge, the MX2-DL Thickness Gauge also features an A-Scan display, allowing users to fully interpret and control measurement readings. The user can select to view either the full waveform (RF) or the rectified waveform (RECT) showing either the positive or the negative cycle of the full waveform.

      Transducer Options

      A wide range of Corrosion Thickness Transducers available 

      DakMaster™

      From inspection to professional reports at the click of a button

  • Key Features
    • Key Features

      Dakota MX Corrosion Thickness Gauges

      Features Explained

      Repeatability / Stability Indicator

      Consisting of 6 vertical bars, when all the bars are fully illuminated and the last digit on the digital thickness value is stable, the gauge is reliably measuring the material thickness.

      High Speed Scan with Minimum Thickness Display

      By significantly increasing the measurement refresh rate this mode allows the user to make scanned passes over the test material. The smallest thickness value is held in memory and displayed when scanning is complete. This feature can also be used in conjunction with the minimum & maximum limit alarm feature (model dependant).

      Differential Mode

      Once a user defined nominal thickness value has been set, the gauge will display the +/- thickness difference from the nominal value entered.

      Limit Alarm Mode

      The user can define minimum and maximum thickness limits. If the measurement falls outside the upper or lower limit a red LED will light and the beeper sounds. A green LED will light to indicate an acceptable thickness.


      V-Path Correction

      Dual element transducers consist of a probe with two crystals (one to transmit and one to receive the sound pulse). The crystals are separated by an acoustic barrier - generating a 'V-shaped' sound path as the sound travels from one element to the other. This path is slightly longer than the direct path therefore V-path correction is used to calculate the correct thickness.

      Measurement Modes Explained

      Pulse Echo (PE): 

      The normal display mode, measures the total thickness from the base of the transducer probe to the material density boundary (typically the back wall). Ideal for pit and flaw detection.

      Echo - Echo Mode (EE):

      Also known as the ThruPaint™ Mode, EE ignores the coating thickness, displaying the material thickness from the top surface of the material to the material density boundary.


      Display Modes Explained

      cg70-b-scab

      Material Thickness Digits Display:

      The standard display on all models, this displays the numerical thickness value in either millimetres (MM) or inches (IN).

      Scan Bar Display:

      A linear graphic display which allows users to graphically monitor changes in thickness readings. As the scale range can be adjusted by the user, this display is ideal for observing tiny variations in material thicknesses.

      B-Scan Display:

      A time based cross sectional 2D block view of the thickness provides a graphical view of the material thickness - ideal for relative depth analysis.

      cg70-a-scan

      A-Scan Display; Full Wave (RF):*

      The A-Scan display shows the sine wave created by the reflected sound, or oscillation, from the material being measured. In RF mode the full wave form is displayed.

      A-Scan Display; Rectified (+ or -):*

      Users can select to view either the positive or the negative cycle of the full waveform (RF). This rectified (RECT) display shows the amplitude of the echo versus the transit time.

      * Available on MX2-DL Model only

  • Product Features
    • Product Features
      Dakota MX Corrosion Thickness Gauges
      Model MX1-DL MX2-DL
      Display Mode
      Material thickness digits display
      B-Scan cross sectional display
      Combined B-Scan and digits display
      Scan Bar Display
      A-Scan Display
      + Rectified, - Rectified, Full Waveform (RF)
      Measurement Rate
      Manual
      8 readings per second
      8 readings per second
      Scan Mode
      250 readings per second
      250 readings per second
      Scan bar display
      10 readings per second
      10 readings per second
      Measurement Resolution
      0.01mm (0.001”)
      0.01mm (0.001”)
      Velocity Calibration Range
      309.88 - 18,542m/s
      (0.0122 - 0.7300in/µs)
      309.88 - 18,542m/s
      (0.0122 - 0.7300in/µs)
      Additional Features
      High Speed Scan Mode
      Differential Mode
      Limit alarm mode
      B-Scan Display Speed
      10 to 200 readings per second
      10 to 200 readings per second
      Calibration Setups
      64 user-definable setups transferable to and from a PC archive
      64 user-definable setups transferable to and from a PC archive
      Gates
      • PE: 1 gate; EE: 2 gates, 1 gate with hold off
      • Adjustable threshold
      Pulser Type
      150 volt square wave pulser
      Square wave pulser with adjustable pulse width (spike, thin, wide)
      Gain
      Manual or automatic gain control (AGC) with 50dB range (depending on mode selected)
      Manual or automatic gain control (AGC) with 40dB range (depending on mode selected)
      Timing
      Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
      20 MHz with ultra low power 8 bit digitizer
      Memory and Data Logging
      • 4GB internal memory
      • Sequential and grid logging
      • Alpha numeric batch identification
      • OBSTRUCT indicates inaccessible locations
      • Bitmap graphic capture and capture viewer
      • 4GB internal memory
      • Sequential and grid logging
      • Alpha numeric batch identification
      • OBSTRUCT indicates inaccessible locations
      • Bitmap graphic capture and capture viewer
      Transducer Probe Type
      Dual element
      Dual element
      Transducer Frequency Range
      1 - 10MHz
      1 - 10MHz
      Transducer Recognition
      Manual - selectable from a list
      Manual - selectable from a list
      V-path / dual path error correction
      Automatic
      Automatic
      Probe Zero
      Manual (via integrated probe disk)
      Manual (via integrated probe disk)
      Display
      1/8 VGA (greyscale)
      62 x 45.7mm (2.4 x 1.8”) viewable area
      1/8 VGA (greyscale)
      62 x 45.7mm (2.4 x 1.8”) viewable area
      Display Refresh Rate
      25Hz
      25Hz
      Units (selectable)
      mm or inches
      mm or inches
      LED Backlight
      on/off/auto
      on/off/auto
      Repeatability / Stability Indicator
  • Technical Information
    • Technical Specification
      Dakota MX Corrosion Thickness Gauges
      Part Number Description Certificate
      Z-160-0005 Dakota MX1-DL Thickness Gauge (MMX-7)
      Calibration Certificate supplied as standard
      Z-149-0006 Dakota MX2-DL Thickness Gauge (MVX)
      Calibration Certificate supplied as standard
      Transducer Probe Type Dual Element
      Measurement Accuracy1 0.01mm (0.001”)
      Memory 4GB Internal Memory
      Operating Temperature -10 to 60ºC (14 to 140ºF)
      Data Output USB
      Power Supply 3 x AA batteries and via USB
      Battery Life Alkaline – 35 hrs, Nicad – 10 hrs and NI-MH – 35 hrs
      Gauge Weight 383g (13.5oz) - including batteries
      Gauge Dimensions 63.5 x 165 x 31.5mm (2.5 x 6.5 x 1.24”)
      Packing List Unit, Selectable Transducer, Couplant, Manual, Plastic Carrying Case, Certificate of Calibration and AA Batteries. PC Software and Data Transfer Cable included with data logging gauges.
      1Measuring range & accuracy depends on material, surface conditions and the transducer selected
      2Approximate battery life, when in continuous measurement mode.
      Certificate of Calibration supplied as standard
  • Standards
    • Standards
      Dakota MX Corrosion Thickness Gauges

      Factory calibration traceable to NIST & MIL-STD-45662

  • Downloads
    • Downloads

        • Dakota MX1-DL Thickness Gauge (MMX-7) Instruction Manual


        • Dakota MX2-DL Thickness Gauge (MVX) Instruction Manual

  • Part Numbers
    • Part Numbers
      Dakota MX Corrosion Thickness Gauges
      • Dakota MX1-DL Corrosion Thickness Gauge
        • Part Number : Z-160-0005
      • Dakota MX2-DL Corrosion Thickness Gauge
        • Part Number : Z-149-0006

Dakota MX Corrosion Thickness Gauges

Dakota MX2-DL Thickness Gauge
CG70-Transducer-intro

The Dakota MX Corrosion Thickness Gauge range have large, easy to read displays and provides users with A and B-Scan options for accurate interpretation of measurements.

Dakota MX2-DL Thickness Gauge measuring container

Versatile

Measures uncoated & coated surfaces

Flexible & easy to use, the Dakota MX Corrosion Thickness range doesn’t just measure uncoated surfaces but can also measure coated surfaces. Using Echo Echo ThruPaint™ Mode (EE), coatings up to 1mm (40mils) are ignored.

CG70-Powerful

Powerful

Store up to 4GB of readings and waveforms or B-Scans

Taking 250 readings per second in scan mode, the internal data logger stores up to 4GB of readings together with their waveforms.

Dakota MX Corrosion Thickness Gauge Screen Close Up

Customisable

Choose & customise the reading display

The Dakota MX ultrasonic thickness gauge range has a choice of display modes allowing the user to select the most appropriate for their needs; Readings, B-Scan, B-Scan combined with readings, Scan bar & the A-Scan on the MX2-DL Corrosion Thickness Gauge.

Summary

Dakota MX Corrosion Thickness Gauges

The Dakota MX corrosion thickness gauge is available in two models: MX1-DL Thickness Gauge and MX2-DL Thickness Gauge. Both models offer 2D cross sectional block view, providing a graphical representation of a material's thickness, ideal for accurate analysis and identification of pits and corroded areas.

MX1-DL Ultrasonic Thickness Gauge: Taking 250 readings per second in scan mode, the internal data logger stores up to 4GB worth of data together with their waveforms.

MX2-DL Ultrasonic Thickness Gauge: As well as all the features of the MX1-DL Thickness Gauge, the MX2-DL Thickness Gauge also features an A-Scan display, allowing users to fully interpret and control measurement readings. The user can select to view either the full waveform (RF) or the rectified waveform (RECT) showing either the positive or the negative cycle of the full waveform.

Transducer Options

A wide range of Corrosion Thickness Transducers available 

DakMaster™

From inspection to professional reports at the click of a button

Downloads

    • Dakota MX1-DL Thickness Gauge (MMX-7) Instruction Manual


    • Dakota MX2-DL Thickness Gauge (MVX) Instruction Manual

Key Features

Dakota MX Corrosion Thickness Gauges

Features Explained

Repeatability / Stability Indicator

Consisting of 6 vertical bars, when all the bars are fully illuminated and the last digit on the digital thickness value is stable, the gauge is reliably measuring the material thickness.

High Speed Scan with Minimum Thickness Display

By significantly increasing the measurement refresh rate this mode allows the user to make scanned passes over the test material. The smallest thickness value is held in memory and displayed when scanning is complete. This feature can also be used in conjunction with the minimum & maximum limit alarm feature (model dependant).

Differential Mode

Once a user defined nominal thickness value has been set, the gauge will display the +/- thickness difference from the nominal value entered.

Limit Alarm Mode

The user can define minimum and maximum thickness limits. If the measurement falls outside the upper or lower limit a red LED will light and the beeper sounds. A green LED will light to indicate an acceptable thickness.


V-Path Correction

Dual element transducers consist of a probe with two crystals (one to transmit and one to receive the sound pulse). The crystals are separated by an acoustic barrier - generating a 'V-shaped' sound path as the sound travels from one element to the other. This path is slightly longer than the direct path therefore V-path correction is used to calculate the correct thickness.

Measurement Modes Explained

Pulse Echo (PE): 

The normal display mode, measures the total thickness from the base of the transducer probe to the material density boundary (typically the back wall). Ideal for pit and flaw detection.

Echo - Echo Mode (EE):

Also known as the ThruPaint™ Mode, EE ignores the coating thickness, displaying the material thickness from the top surface of the material to the material density boundary.


Display Modes Explained

cg70-b-scab

Material Thickness Digits Display:

The standard display on all models, this displays the numerical thickness value in either millimetres (MM) or inches (IN).

Scan Bar Display:

A linear graphic display which allows users to graphically monitor changes in thickness readings. As the scale range can be adjusted by the user, this display is ideal for observing tiny variations in material thicknesses.

B-Scan Display:

A time based cross sectional 2D block view of the thickness provides a graphical view of the material thickness - ideal for relative depth analysis.

cg70-a-scan

A-Scan Display; Full Wave (RF):*

The A-Scan display shows the sine wave created by the reflected sound, or oscillation, from the material being measured. In RF mode the full wave form is displayed.

A-Scan Display; Rectified (+ or -):*

Users can select to view either the positive or the negative cycle of the full waveform (RF). This rectified (RECT) display shows the amplitude of the echo versus the transit time.

* Available on MX2-DL Model only

Product Features
Dakota MX Corrosion Thickness Gauges
Model MX1-DL MX2-DL
Display Mode
Material thickness digits display
B-Scan cross sectional display
Combined B-Scan and digits display
Scan Bar Display
A-Scan Display
+ Rectified, - Rectified, Full Waveform (RF)
Measurement Rate
Manual
8 readings per second
8 readings per second
Scan Mode
250 readings per second
250 readings per second
Scan bar display
10 readings per second
10 readings per second
Measurement Resolution
0.01mm (0.001”)
0.01mm (0.001”)
Velocity Calibration Range
309.88 - 18,542m/s
(0.0122 - 0.7300in/µs)
309.88 - 18,542m/s
(0.0122 - 0.7300in/µs)
Additional Features
High Speed Scan Mode
Differential Mode
Limit alarm mode
B-Scan Display Speed
10 to 200 readings per second
10 to 200 readings per second
Calibration Setups
64 user-definable setups transferable to and from a PC archive
64 user-definable setups transferable to and from a PC archive
Gates
• PE: 1 gate; EE: 2 gates, 1 gate with hold off
• Adjustable threshold
Pulser Type
150 volt square wave pulser
Square wave pulser with adjustable pulse width (spike, thin, wide)
Gain
Manual or automatic gain control (AGC) with 50dB range (depending on mode selected)
Manual or automatic gain control (AGC) with 40dB range (depending on mode selected)
Timing
Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
20 MHz with ultra low power 8 bit digitizer
Memory and Data Logging
• 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewer
• 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewer
Transducer Probe Type
Dual element
Dual element
Transducer Frequency Range
1 - 10MHz
1 - 10MHz
Transducer Recognition
Manual - selectable from a list
Manual - selectable from a list
V-path / dual path error correction
Automatic
Automatic
Probe Zero
Manual (via integrated probe disk)
Manual (via integrated probe disk)
Display
1/8 VGA (greyscale)
62 x 45.7mm (2.4 x 1.8”) viewable area
1/8 VGA (greyscale)
62 x 45.7mm (2.4 x 1.8”) viewable area
Display Refresh Rate
25Hz
25Hz
Units (selectable)
mm or inches
mm or inches
LED Backlight
on/off/auto
on/off/auto
Repeatability / Stability Indicator
Technical Specification
Dakota MX Corrosion Thickness Gauges
Part Number Description Certificate
Z-160-0005 Dakota MX1-DL Thickness Gauge (MMX-7)
Calibration Certificate supplied as standard
Z-149-0006 Dakota MX2-DL Thickness Gauge (MVX)
Calibration Certificate supplied as standard
Transducer Probe Type Dual Element
Measurement Accuracy1 0.01mm (0.001”)
Memory 4GB Internal Memory
Operating Temperature -10 to 60ºC (14 to 140ºF)
Data Output USB
Power Supply 3 x AA batteries and via USB
Battery Life Alkaline – 35 hrs, Nicad – 10 hrs and NI-MH – 35 hrs
Gauge Weight 383g (13.5oz) - including batteries
Gauge Dimensions 63.5 x 165 x 31.5mm (2.5 x 6.5 x 1.24”)
Packing List Unit, Selectable Transducer, Couplant, Manual, Plastic Carrying Case, Certificate of Calibration and AA Batteries. PC Software and Data Transfer Cable included with data logging gauges.
1Measuring range & accuracy depends on material, surface conditions and the transducer selected
2Approximate battery life, when in continuous measurement mode.
Certificate of Calibration supplied as standard
Standards
Dakota MX Corrosion Thickness Gauges

Factory calibration traceable to NIST & MIL-STD-45662

Part Numbers
Dakota MX Corrosion Thickness Gauges
  • Dakota MX1-DL Corrosion Thickness Gauge
    • Part Number : Z-160-0005
  • Dakota MX2-DL Corrosion Thickness Gauge
    • Part Number : Z-149-0006