Dakota BT1-DL Bolt Tension Monitor

The Dakota BT1-DL Bolt Tension Monitor uses ultrasound to precisely measure fastener elongation, time (nanoseconds), load, stress & %strain.
- Resumen
-
Resumen
-
When nuts and bolts are fastened together under load the action of tightening the nut increases the force applied to the bolt causing elongation.
By using ultrasonics, bolt tension monitors are not affected by temperature, friction or resistance factors affecting the accuracy of standard torque measurement techniques - giving the Dakota BT1-DL Bolt Tension Monitor accuracy within 0.0001mm (0.00001 inch).
Using the gauge's USB interface together with the optional shut off accessory the gauge can be programmed to automatically stop the tightening process when the appropriate load has been applied.
Features:
- Range of display & measurement options including: Elongation, Load, Stress, and %Strain, RF, Rectified, Large Digits with Limits Bar
- Temperature compensation to counteract measurement irregularity caused by temperature change
- Data storage capability: 4GB internal memory
- Auto Set feature automatically optimizes detection and adjusts display
- Hi/Lo Alarm tolerance limits work in conjunction with the data port
-
- Características más importantes
-
Características más importantes
Dakota BT1-DL Bolt Tension Monitor
Applications
Wind Turbines
Automotive Frames
Bridge Structures
Theme Parks
Firmware Upgrades
Regularly checking and updating your firmware is crucial for maintaining performance, and ensuring compatibility with new features.
Make sure your Dakota Bolt Tension Monitor is running the latest firmware, select your gauge below.
-
- Características del medidor
-
Dakota NDT BT Bolt Tension Monitors
Características del medidorDakota BT1-DL Bolt Tension Monitor
Model BT1-DL Display Mode Pantalla dígitos de espesor de material A-Scan Rectificado +/- (vista de media onda) o RF (vista de forma de onda completa)BTM Measurement Range PE - 25.4 - 25,400mm (1 - 999”)Resolución 0,001mm (0,0001”) or 0,0001mm (0,00001”) switchableMeasurement Rate Manual 8 lecturas por segundoRango de calibración de velocidad 1250 - 13,995m/s (0.0492 - 0.5510 in/μs)Compensación de Temperatura Modo alarma de límite Memoria y registro de datos Memoria interna de 4 GB
Secuencial y registro de cuadricula
Captura de gráfico de mapa de bits y visor de capturaOpciones de calibración Automática, fija, de uno y de dos puntosTipo de sonda de transductor elemento sencilloRango de frecuencia de transductor 1 - 10MHzPantalla Pantalla VGA de escala de grises de 1/8” (240 x 160 píxeles)
Área visualizable de 62 x 45,7 mm (2,4 x 1,8”)Unidades (seleccionable) in/mm, μs, °F/°CLuz de Fondo LED on / off / autoRepetibilidad / Indicador de Estabilidad Indicador de Pila Baja Modo de Ahorro de Pila AutomáticoTipo de Conector de Transductor Microdot, Lemo and BNCInterfaz USB Sensor de temperatura LEMO 1 de 5 patillasFrecuencia de actualización de pantalla 30 HzCronometraje Cronometraje de precisión de TCXO (oscilador controlado por cristal termorregulado) con digitalizador de potencia ultrabaja de 100 MHz y 8 bits de un solo disparoTipo pulso Onda cuadrada. 100, 150 y 200 voltios seleccionables. Opciones seleccionables: pico, delgado y ancho. De 80 a 400 nsAmortiguamiento 50, 75, 100, 300, 600, & 1500ohmsBanda de frecuencias Filtro de banda ancha de 1,8 - 19 MHz (-3 dB)Linealidad horizontal +/- 0.4% FSWLinealidad vertical +/- 1% FSHLinealidad de amplificador +/- 1 dBMedición de amplitud 0 a 100% FSH, con 1% resoluciónRetardo 25 400 mm (0 - 999,9”) a la velocidad del aceroPortal de medición Un portal con alarma sonora y visual. Amplitud de 5-95 %, pasos de 1 %Configuraciones 64 configuraciones personalizadas definidas por el usuario; el usuario también puede editar las configuraciones de fábricaConfiguración automática Automatiza el proceso de configuración de detección, alcance y visualización para cada tornilloLímites de alarmas Tolerancias Hi (alta)/Low (baja) ajustables con LED y pitidoCalibración de campo Curva de corrección de vector o regresión para mayor precisión empleando carga y estrésBarra de límites de alarmas Límites de alarmas Hi (alto) y Lo (bajo) para visualización de un rango de tolerancia aceptableDetección Cruce ceroTiempo NanosegundosElongación Cambio de longitud (pulgadas/mm)Carga Carga de fuerza aplicada (libras KIP o megapascales MPa)Estrés Fuerza por estrés de unidad de área aplicado (pulgadas por pulgada o milímetros por milímetro)Tensión Ratio elongación-longitud efectivaMateriales de tornillos Seleccione los tipos de una lista preestablecida o personalizadaGlue-On Disponible para tornillos cortos con elongación mínima/corta para eliminar errores de colocación del transductor.
-
Dakota NDT BT Bolt Tension Monitors
- Información técnica
-
Características TécnicasDakota BT1-DL Bolt Tension Monitor
Referencia Descripción Certificado Z-156-0008 Dakota BT1-DL Bolt Tension Monitor (MiniMax)
Temperatura de funcionamiento -10 to 60ºC (14 to 140ºF) Fuente de alimentación 3 pilas AA y a través de USB Duración de las pilas Alcalinas: 35 horas; Nicad: 10 horas; NI-MH: 35 horas Peso del medidor 383g (13,5oz) - incluidas pilas Dimensiones del medidor 63,5 x 165 x 31,5mm Lista de empaque Unit, 3 AA Batteries, 4 oz. Bottle of Couplant, USB Type A to Type C Transfer Cable, Carrying Case, 10’ Lemo to Microdot Transducer cable, PC Utility Software (download from website), Operation Manual and Certification. ● Certificate supplied as standard
-
- Normas
-
NormasDakota BT1-DL Bolt Tension Monitor
Factory calibration traceable to NIST & MIL-STD-45662A
-
- Descargas
-
Descargas
- Referencia
-
ReferenciaDakota BT1-DL Bolt Tension MonitorNo data found!!
-
Dakota BT1-DL Bolt Tension Monitor (MiniMax)- Referencia : Z-156-0008
-
- Home
- Dakota BT1-DL Bolt Tension Monitor
Dakota BT1-DL Bolt Tension Monitor

The Dakota BT1-DL Bolt Tension Monitor uses ultrasound to precisely measure fastener elongation, time (nanoseconds), load, stress & %strain.
Resumen
Dakota BT1-DL Bolt Tension Monitor
When nuts and bolts are fastened together under load the action of tightening the nut increases the force applied to the bolt causing elongation.
By using ultrasonics, bolt tension monitors are not affected by temperature, friction or resistance factors affecting the accuracy of standard torque measurement techniques - giving the Dakota BT1-DL Bolt Tension Monitor accuracy within 0.0001mm (0.00001 inch).
Using the gauge's USB interface together with the optional shut off accessory the gauge can be programmed to automatically stop the tightening process when the appropriate load has been applied.
Features:
- Range of display & measurement options including: Elongation, Load, Stress, and %Strain, RF, Rectified, Large Digits with Limits Bar
- Temperature compensation to counteract measurement irregularity caused by temperature change
- Data storage capability: 4GB internal memory
- Auto Set feature automatically optimizes detection and adjusts display
- Hi/Lo Alarm tolerance limits work in conjunction with the data port
Características más importantes
Dakota BT1-DL Bolt Tension Monitor
Applications
Wind Turbines
Automotive Frames
Bridge Structures
Theme Parks
Firmware Upgrades
Regularly checking and updating your firmware is crucial for maintaining performance, and ensuring compatibility with new features.
Make sure your Dakota Bolt Tension Monitor is running the latest firmware, select your gauge below.
Dakota NDT BT Bolt Tension MonitorsCaracterísticas del medidorDakota BT1-DL Bolt Tension MonitorModel BT1-DL Display Mode Pantalla dígitos de espesor de material A-Scan Rectificado +/- (vista de media onda) o RF (vista de forma de onda completa)BTM Measurement Range PE - 25.4 - 25,400mm (1 - 999”)Resolución 0,001mm (0,0001”) or 0,0001mm (0,00001”) switchableMeasurement Rate Manual 8 lecturas por segundoRango de calibración de velocidad 1250 - 13,995m/s (0.0492 - 0.5510 in/μs)Compensación de Temperatura Modo alarma de límite Memoria y registro de datos Memoria interna de 4 GB
Secuencial y registro de cuadricula
Captura de gráfico de mapa de bits y visor de capturaOpciones de calibración Automática, fija, de uno y de dos puntosTipo de sonda de transductor elemento sencilloRango de frecuencia de transductor 1 - 10MHzPantalla Pantalla VGA de escala de grises de 1/8” (240 x 160 píxeles)
Área visualizable de 62 x 45,7 mm (2,4 x 1,8”)Unidades (seleccionable) in/mm, μs, °F/°CLuz de Fondo LED on / off / autoRepetibilidad / Indicador de Estabilidad Indicador de Pila Baja Modo de Ahorro de Pila AutomáticoTipo de Conector de Transductor Microdot, Lemo and BNCInterfaz USB Sensor de temperatura LEMO 1 de 5 patillasFrecuencia de actualización de pantalla 30 HzCronometraje Cronometraje de precisión de TCXO (oscilador controlado por cristal termorregulado) con digitalizador de potencia ultrabaja de 100 MHz y 8 bits de un solo disparoTipo pulso Onda cuadrada. 100, 150 y 200 voltios seleccionables. Opciones seleccionables: pico, delgado y ancho. De 80 a 400 nsAmortiguamiento 50, 75, 100, 300, 600, & 1500ohmsBanda de frecuencias Filtro de banda ancha de 1,8 - 19 MHz (-3 dB)Linealidad horizontal +/- 0.4% FSWLinealidad vertical +/- 1% FSHLinealidad de amplificador +/- 1 dBMedición de amplitud 0 a 100% FSH, con 1% resoluciónRetardo 25 400 mm (0 - 999,9”) a la velocidad del aceroPortal de medición Un portal con alarma sonora y visual. Amplitud de 5-95 %, pasos de 1 %Configuraciones 64 configuraciones personalizadas definidas por el usuario; el usuario también puede editar las configuraciones de fábricaConfiguración automática Automatiza el proceso de configuración de detección, alcance y visualización para cada tornilloLímites de alarmas Tolerancias Hi (alta)/Low (baja) ajustables con LED y pitidoCalibración de campo Curva de corrección de vector o regresión para mayor precisión empleando carga y estrésBarra de límites de alarmas Límites de alarmas Hi (alto) y Lo (bajo) para visualización de un rango de tolerancia aceptableDetección Cruce ceroTiempo NanosegundosElongación Cambio de longitud (pulgadas/mm)Carga Carga de fuerza aplicada (libras KIP o megapascales MPa)Estrés Fuerza por estrés de unidad de área aplicado (pulgadas por pulgada o milímetros por milímetro)Tensión Ratio elongación-longitud efectivaMateriales de tornillos Seleccione los tipos de una lista preestablecida o personalizadaGlue-On Disponible para tornillos cortos con elongación mínima/corta para eliminar errores de colocación del transductor.Características TécnicasDakota BT1-DL Bolt Tension MonitorReferencia Descripción Certificado Z-156-0008 Dakota BT1-DL Bolt Tension Monitor (MiniMax)
Temperatura de funcionamiento -10 to 60ºC (14 to 140ºF) Fuente de alimentación 3 pilas AA y a través de USB Duración de las pilas Alcalinas: 35 horas; Nicad: 10 horas; NI-MH: 35 horas Peso del medidor 383g (13,5oz) - incluidas pilas Dimensiones del medidor 63,5 x 165 x 31,5mm Lista de empaque Unit, 3 AA Batteries, 4 oz. Bottle of Couplant, USB Type A to Type C Transfer Cable, Carrying Case, 10’ Lemo to Microdot Transducer cable, PC Utility Software (download from website), Operation Manual and Certification. ● Certificate supplied as standard - Referencia
-