Dakota BT2-DL Benchtop Bolt Tension Monitor

The Dakota BT2-DL is a high-precision benchtop Bolt Tension Monitor designed to measure bolt tension, elongation, load, and stress using advanced ultrasonic technology. Unlike standard torque methods, the BT2-DL provides accuracy within ±0.00001 inches (0.0001 mm) for fasteners up to 100 feet in length.
- Zusammenfassung
-
Zusammenfassung
-
It incorporates all of the great features of the Dakota BT1-DL Bolt Tension Monitor, with some added benefits in terms of features, hardware, speed, and length. Dakota BT2-DL Ultrasonic Bolt Tension Monitor very accurately measures fasteners up to 100 feet in length, and sports our very best effort to date…in terms of overall performance/power!
-
- Hauptmerkmale
-
Hauptmerkmale
Dakota BT2-DL Benchtop Bolt Tension Monitor
Firmware Upgrades
Regularly checking and updating your firmware is crucial for maintaining performance, and ensuring compatibility with new features.
Make sure your Dakota Bolt Tension Monitor is running the latest firmware, select your gauge below.
-
- Produkteigenschaften
-
Dakota NDT BT Benchtop Bolt Tension Monitor
ProdukteigenschaftenDakota BT2-DL Benchtop Bolt Tension Monitor
Model BT2-DL Display Mode Numerische Materialdickenanzeige A-Bild-Anzeige Gerichtet +/- (Halbwellenanzeige), oder RF (Vollwellenanzeige)BTM Measurement Range PE - 25.4 - 25,400mm (1 - 999”), EE, EEVAuflösung +/- 0.0001mm (+/- 0.00001")Measurement Rate Manuell 8 Messwerte pro SekundeGeschwindigkeitskalibrierbereich 1250 - 13.995m/s (0,0492 - 0,5510 in/μs)Temperaturkompensation Grenzwertalarmmodus Speicher und Datenaufzeichnung 4 GB interner Speicher
Sequenz- und Rasteraufzeichnung
Bitmap-Grafikerfassung und -AnzeigeKalibrieroptionen Automatisch, Fix, Ein- und ZweipunktMesskopfsondentyp ein ElementMesskopffrequenzbereich 1 - 10MHzDisplay Blanview sunlight readable QVGA TFT color display (320 x 240 pixels)
Viewable area 4.54 x 3.40 in (115.2 x 86.4 mm), or 5.7 in (144.78 mm) diagonalEinheiten (wählbar) in/mm, μsLED-Hintergrundbeleuchtung ein / aus / automatischWiederholgenauigkeits-/Stabilitätsanzeige Batterieladezustandsanzeige Batteriesparmodus automatischMesskopfanschlusstyp Microdot, Lemo and BNCUSB-Schnittstelle Temperatursensor YesDisplayaktualisierungsrate 60HzTiming Temperaturkontrollierter Präzisions-Quarz-Oszillator (TCXO). Timing mit einem einzigen Signal von 100MHz mit ultra-energiesparendem 8-Bit-DigitizerImpulsgebertyp Spike, Square Wave & Tone Burst.Pulser Voltage: 100 – 400v
Selectable step options Spike, Thin, Wide, HV Spike, HV Thin, HV Wide, TB .5MHz, TB 1MHz, TB 2MHz, TB 5MHz, TB 10 MHz. Spike 40 ns, Square Wave 80 to 400 ns, Tone Burst 50 ns to 1 microsecondGedämpft 50, 75, 100, 300, 600, & 1500ohmsFrequenzbereich Breitband 1,8 - 19 MHz (-3 dB) FilterHorizontale Linearität +/- 0.4% FSWVertikale Linearität +/- 1% FSHVerstärkerlinearität +/- 1 dBAmplitudenmessung 0 bis 100% FSH mit 1% AuflösungVerzögerung 25.400 mm (0 - 999,9”) bei Geschwindigkeit von StahlMessblende Three independent gates depending on measurement mode selected, with audible and visual alarms. Amplitude 5-95%, 1% stepsKonfigurationen 64 benutzerdefinierbare Konfigurationen; werksseitige Konfigurationen sind ebenfalls benutzereditierbarAuto-Einstellung Automatisiert das Einstellen von Detektion, Umfang und Display für jede SchraubeAlarmgrenzwerte Einstellbare Mindest-/Höchsttoleranzen mit visuellem LED- und akustischem WarnsignalFeldkalibrierung Vektor- oder Regressionskorrekturkurve für höhere Genauigkeit mit Last und SpannungAlarmgrenzwertleiste Obere und untere Alarmgrenzwerte für die Anzeige eines akzeptablen ToleranzbereichsDetektion Zero CrossingZeit NanosekundenVerlängerung Längenänderung (Zoll/mm)Last Wirklast (Pound KIP oder Megapascal MPa)Spannung Kraft für angewandte Flächenspannung (Zoll auf Zoll oder Millimeter auf Millimeter)Dehnung in % Verhältnis der Verlängerung zur effektiven LängeSchraubensorten Typenauswahl aus einer voreingestellten oder benutzerdefinierten ListeVerklebt Zur Eliminierung von Messkopfpositionsfehlern für Schrauben mit minimaler/ kleiner Verlängerung erhältlich.
-
Dakota NDT BT Benchtop Bolt Tension Monitor
- Technische Informationen
-
Technische SpezifikationenDakota BT2-DL Benchtop Bolt Tension Monitor
Bestellnummer Beschreibung Zertifikat Z-197-0001 Dakota BT2-DL Benchtop Bolt Tension Monitor (Max II)
Betriebstemperatur -10 bis 60ºC (14 bis 140ºF) Stromversorgung Lithium Ion Pack (supplied) or 6 x AA batteries Batteriegebrauchsdauer Lithium Pack: 18hrs, Alkaline: 12 hrs, Nicad: 5 hrs, NI-MH: 12 hrs Gerätegewicht 2.04kg (4.5lbs) - including batteries Geräteabmessungen 216 x 165 x 70mm (8.5 x 6.5 x 2.5”) Packliste Unit, Lithium Pack, 4 oz. Bottle of Couplant, USB Type A to Type B Transfer Cable, Carrying Case, 10’ Lemo 00 to Microdot Transducer Cable, PC Utility Software (download from website), Operation Manual and Certification. ● Certificate supplied as standard
-
- Verwendbar gemäß
-
Verwendbar gemäßDakota BT2-DL Benchtop Bolt Tension Monitor
Factory calibration traceable to NIST & MIL-STD-45662A
-
- Downloads
-
Downloads
- Bestellnummer
-
BestellnummerDakota BT2-DL Benchtop Bolt Tension MonitorNo data found!!
-
Dakota BT2-DL Benchtop Bolt Tension Monitor (Max II)- Bestellnummer : Z-197-0001
-
- Home
- Dakota BT2-DL Benchtop Bolt Tension Monitor
Dakota BT2-DL Benchtop Bolt Tension Monitor

The Dakota BT2-DL is a high-precision benchtop Bolt Tension Monitor designed to measure bolt tension, elongation, load, and stress using advanced ultrasonic technology. Unlike standard torque methods, the BT2-DL provides accuracy within ±0.00001 inches (0.0001 mm) for fasteners up to 100 feet in length.
Zusammenfassung
Dakota BT2-DL Benchtop Bolt Tension Monitor
It incorporates all of the great features of the Dakota BT1-DL Bolt Tension Monitor, with some added benefits in terms of features, hardware, speed, and length. Dakota BT2-DL Ultrasonic Bolt Tension Monitor very accurately measures fasteners up to 100 feet in length, and sports our very best effort to date…in terms of overall performance/power!
Hauptmerkmale
Dakota BT2-DL Benchtop Bolt Tension Monitor
Firmware Upgrades
Regularly checking and updating your firmware is crucial for maintaining performance, and ensuring compatibility with new features.
Make sure your Dakota Bolt Tension Monitor is running the latest firmware, select your gauge below.
Dakota NDT BT Benchtop Bolt Tension MonitorProdukteigenschaftenDakota BT2-DL Benchtop Bolt Tension MonitorModel BT2-DL Display Mode Numerische Materialdickenanzeige A-Bild-Anzeige Gerichtet +/- (Halbwellenanzeige), oder RF (Vollwellenanzeige)BTM Measurement Range PE - 25.4 - 25,400mm (1 - 999”), EE, EEVAuflösung +/- 0.0001mm (+/- 0.00001")Measurement Rate Manuell 8 Messwerte pro SekundeGeschwindigkeitskalibrierbereich 1250 - 13.995m/s (0,0492 - 0,5510 in/μs)Temperaturkompensation Grenzwertalarmmodus Speicher und Datenaufzeichnung 4 GB interner Speicher
Sequenz- und Rasteraufzeichnung
Bitmap-Grafikerfassung und -AnzeigeKalibrieroptionen Automatisch, Fix, Ein- und ZweipunktMesskopfsondentyp ein ElementMesskopffrequenzbereich 1 - 10MHzDisplay Blanview sunlight readable QVGA TFT color display (320 x 240 pixels)
Viewable area 4.54 x 3.40 in (115.2 x 86.4 mm), or 5.7 in (144.78 mm) diagonalEinheiten (wählbar) in/mm, μsLED-Hintergrundbeleuchtung ein / aus / automatischWiederholgenauigkeits-/Stabilitätsanzeige Batterieladezustandsanzeige Batteriesparmodus automatischMesskopfanschlusstyp Microdot, Lemo and BNCUSB-Schnittstelle Temperatursensor YesDisplayaktualisierungsrate 60HzTiming Temperaturkontrollierter Präzisions-Quarz-Oszillator (TCXO). Timing mit einem einzigen Signal von 100MHz mit ultra-energiesparendem 8-Bit-DigitizerImpulsgebertyp Spike, Square Wave & Tone Burst.Pulser Voltage: 100 – 400v
Selectable step options Spike, Thin, Wide, HV Spike, HV Thin, HV Wide, TB .5MHz, TB 1MHz, TB 2MHz, TB 5MHz, TB 10 MHz. Spike 40 ns, Square Wave 80 to 400 ns, Tone Burst 50 ns to 1 microsecondGedämpft 50, 75, 100, 300, 600, & 1500ohmsFrequenzbereich Breitband 1,8 - 19 MHz (-3 dB) FilterHorizontale Linearität +/- 0.4% FSWVertikale Linearität +/- 1% FSHVerstärkerlinearität +/- 1 dBAmplitudenmessung 0 bis 100% FSH mit 1% AuflösungVerzögerung 25.400 mm (0 - 999,9”) bei Geschwindigkeit von StahlMessblende Three independent gates depending on measurement mode selected, with audible and visual alarms. Amplitude 5-95%, 1% stepsKonfigurationen 64 benutzerdefinierbare Konfigurationen; werksseitige Konfigurationen sind ebenfalls benutzereditierbarAuto-Einstellung Automatisiert das Einstellen von Detektion, Umfang und Display für jede SchraubeAlarmgrenzwerte Einstellbare Mindest-/Höchsttoleranzen mit visuellem LED- und akustischem WarnsignalFeldkalibrierung Vektor- oder Regressionskorrekturkurve für höhere Genauigkeit mit Last und SpannungAlarmgrenzwertleiste Obere und untere Alarmgrenzwerte für die Anzeige eines akzeptablen ToleranzbereichsDetektion Zero CrossingZeit NanosekundenVerlängerung Längenänderung (Zoll/mm)Last Wirklast (Pound KIP oder Megapascal MPa)Spannung Kraft für angewandte Flächenspannung (Zoll auf Zoll oder Millimeter auf Millimeter)Dehnung in % Verhältnis der Verlängerung zur effektiven LängeSchraubensorten Typenauswahl aus einer voreingestellten oder benutzerdefinierten ListeVerklebt Zur Eliminierung von Messkopfpositionsfehlern für Schrauben mit minimaler/ kleiner Verlängerung erhältlich.Technische SpezifikationenDakota BT2-DL Benchtop Bolt Tension MonitorBestellnummer Beschreibung Zertifikat Z-197-0001 Dakota BT2-DL Benchtop Bolt Tension Monitor (Max II)
Betriebstemperatur -10 bis 60ºC (14 bis 140ºF) Stromversorgung Lithium Ion Pack (supplied) or 6 x AA batteries Batteriegebrauchsdauer Lithium Pack: 18hrs, Alkaline: 12 hrs, Nicad: 5 hrs, NI-MH: 12 hrs Gerätegewicht 2.04kg (4.5lbs) - including batteries Geräteabmessungen 216 x 165 x 70mm (8.5 x 6.5 x 2.5”) Packliste Unit, Lithium Pack, 4 oz. Bottle of Couplant, USB Type A to Type B Transfer Cable, Carrying Case, 10’ Lemo 00 to Microdot Transducer Cable, PC Utility Software (download from website), Operation Manual and Certification. ● Certificate supplied as standardVerwendbar gemäßDakota BT2-DL Benchtop Bolt Tension MonitorFactory calibration traceable to NIST & MIL-STD-45662A
- Bestellnummer
-